• Call (800) 524-3455 for pricing

1 min. EOGas video

EOGas Sterilization System

  • Andersen's Gas Diffusion Technology
  • The only multiload sterilizer on the market
  • Our Multiload EOGas system
  • Gas diffusion eliminates "dead space" around loads by delivering Ethylene Oxide directly to the load. No harsh preconditioning is required, treating sensitive products gently and effectively.
  • Add and remove bags at any time!
  • Other systems: one load at a time
  • Conventional systems fill the entire chamber with EO, possibly overdosing product to compensate for "dead space"around loads. Forced pre-conditioning in a deep vacuum under high humidity may damage sensitive products.
  • One load at a time

Benefits of the Andersen EOGas System

  • 100% Ethylene Oxide, no CFCs or HCFCs
  • Sterilizes and aerates in the same cabinet
  • Power outage back-up protection
  • Digital display with load tracking function
  • EPA-registered; certifications to international standards
  • Complies with current OSHA Regulations for personnel exposure
  • Economical gas disposal emissions abatement equipment available
  • All sterilizers available either 110V 60Hz or 220V 50Hz

Andersen's EOGas system links our unique gas diffusion technology with advanced micro-processor control. The micro-processor keeps track of the bags in the sterilizer, and the operator may load new bags or unload finished bags while others are in process. For tracking purposes, when a bag is loaded, two labels are printed: one is placed in the log book, one is placed in the bag. Unique multi-load capabilities eliminates batch load restrictions.

Innovative unit-dose cartridges match the actual load volume, greatly reducing gas consumption.

Easy installation requires no compressed air or water source, only a dedicated outside vent and a single-phase AC outlet.

EOGas Cartridge

80% less gas than the competition.

With Andersen's match load to cartridge method you never have to worry about tanks of EtO. Andersen Products offers cutting-edge technologies and over 30 years of expertise in sterilization with the only system that offers multiload capability.

Match Load Volume. Two bag sizes available:

  • The AN1005 is 18"x 24" bag size with only 5 grams of EtO used.
  • The AN1006 is 22"x36" bag siz with only 11 grams of EtO used.

Cost Effective Kits include:

  • 25 EOGas 100% EtO cartridges
  • 25 Humidichip® relative humidity stabilizing chips
  • 25 EOGas Dosimeters®
  • 25 corresponding size Sterilization Bags

Its robust design and polyurethane body make the EOGas cartridge one of the most reliable vehicles for releasing the ethylene oxide gas.

Double protection of the trigger via a plastic lock and a safety seal ensures operator safety.